152 XgOS User’s Guide September 2014
Parameters
Example: Display FC Cards
Display the properties of all Fibre Channel cards.
Example: Display FC Card Utilization
Memory utilization is available for fibre channel cards. By displaying memory
utilization, you can get information about how much of the FC card’s processing
power is being used by different processes. The utilization numbers are for the entire
card and all vHBAs terminated on it. Display the utilization by issuing the show
fc-card <number> utilization command.
Parameter Description
*|<slot> Specifies the physical slot to which the command will be
applied. An asterisk (*) specifies all available FC cards.
-descr=<text> Applies a text description to the FC module. Quotes are
required around multiple words containing spaces in
between.
<port-number>
Specifies a particular Fibre Channel port for which
information will be displayed.
<wildcard> Allows specifying selected wildcard characters (for
example, *) to facilitate executing a command for one or
more vHBAs.
show fc-card
slot state descr type vhbas qos enables
-----------------------------------------------------------------
1 up/up sanFc2Port4GbLrCard 9 -
8 up/up sanFc2Port4GbLrCard 4 10 q
2 records displayed
show fc-card 8 utilization
name total-util no-rsrs-p0 no-rsrs-p1 no-read-mem no-write-mem
-----------------------------------------------------------------
8 48900050 990 40 0 0
1 record displayed