Chapter 8 Virtual Host Bus Adapters (vHBAs) 149
Bind After prescan
The ideal scenario is to bind the prescan-discovery results to a host server. XgOS
supports binding the server profile with the phys-con after a prescan is complete, as
long as you follow the correct configuration order.
Follow these steps to perform a prescan then bind the server profile:
1. Create an unbound server profile:
2. Create a vHBA under this unbound server:
3. Set this vHBA to prescan state:
4. Display the targets:
From now on if there are any RSCN changes, the targets will also be updated
accordingly.
Note At this point, you can also specify the target order by integrating persistent
mapping with prescan. See “Persistent Binding” on page 142. If you do, be sure to
issue remove-prescan before binding.
wwpn 50:01:39:70:00:00:F1:02
map
lun-mask
local-id 0
------------------------------------------------------------------------
1 record displayed
add server-profile III
add vhba vhbaiii.III 4/1
set vhba vhbaiii.III prescan
show vhba vhbaiii.III targets