150 XgOS User’s Guide September 2014
5. If you are satisfied with the results, bind the server-profile:
From now on, this vHBA has become a normal vHBA. You can run rescan against
it:
Note You can no longer run prescan against this normal vHBA.
Example: remove-prescan
You can issue prescan several times. However to detect LUN changes, the prior
prescan state must be removed (remove-prescan) from the vHBA before you can
re-issue prescan again:
Detect LUN Changes rescan
RSCN does not support reporting LUN state changes. For the Oracle Fabric
Interconnect to detect LUN changes, you must manually run rescan for a vHBA.
The rescan process runs to completion, then displays information for all vHBAs in
down state.
To detect LUN changes for a bound (normal) vHBA:
1. Create a bound server profile:
2. Create a vHBA under this bound server:
3. Display the targets:
set server-profile III connect titan@ServerPort23
set vhba vhbaiii.III rescan
set vhba vhbaiii.III remove-prescan
set vhba vhbaiii.III prescan
show vhba vhbaiii.III targets
add server-profile titan titan@ServerPort23
add vhba vhba888.titan 4/1
show vhba vhba888.titan targets